Residual Current Device

Do you need fuses? Ahlsell helps you find installation material for all your electrical jobs. Whether you work with commercial properties or private residences, we have the range for your next project. We offer products from several well-known suppliers. Here you will find wall sockets, cable ladders, and accessories for easy installations. We also offer smart wall sockets, switches, and dimmers from several major suppliers. Modern products for modern solutions. All the installation material you need under one roof. A job well done begins with good materials. Explore our wide range of fuses, installation materials, and accessories here in the online store or visit your nearest Ahlsell shop.

Earth fault breaker 5SV3 4-pole, with neutral to left
Siemens
Earth fault breaker 5SV3 4-pole, with neutral to left
Art. no.: 2167805
An earth fault breaker is used as a supplementary protection to prevent personal injury and fires caused by an electric overload through insulation errors, damage or unintentional contact. For personal protection, and earth fault breaker is used with 10 or 30 mA error current sensitivity and for fire protection, and earth fault breaker with max 300 mA error current sensitivity is used. Earth fault breaker type A can handle detecting both alternating current and pulsating direct current errors. Each earth fault breaker must have its own neutral base/neutral bar, and neutral must be separated from the protective conductor. Earth fault breaker is connected upstream of the group or electrical apparatus to be protected. The earth fault breaker’s must be checked frequently with the test button that is on every earth fault breaker. When the test button is pressed, a fault current is simulated and the earth fault breaker must trigger.
Earth fault breaker 2-pole type A, Quick Connect
Hager
Earth fault breaker 2-pole type A, Quick Connect
Art. no.: 2163812
Earth fault breakers are used as personal or installation protection for conduction to earth that is greater than 10, 30 or 300 mA. All earth fault breakers are surge-proof, which means that they are protected against unnecessary disconnections from electric mains due to transients or what we call spikes. All earth fault breakers type A are DC pulse sensitive and can thus break the main circuit in the event of fault currents other than sinusoidal. A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. Semilog labelling program can be downloaded at hager.se. Earth fault breaker with soft leads can be connected under phase rail with screw connectors. The phase rail is simply pressed into place; you need never re-tighten. NOTE: Hager’s KDNxxx phase rail must be used.
Earth fault breaker 4-pole type A Quick Connect
Hager
Earth fault breaker 4-pole type A Quick Connect
Art. no.: 2163820
Earth fault breakers are used as personal or installation protection for conduction to earth that is greater than 10, 30 or 300 mA. All earth fault breakers are surge-proof, which means that they are protected against unnecessary disconnections from electric mains due to transients or what we call spikes. All earth fault breakers type A are DC pulse sensitive and can thus break the main circuit in the event of fault currents other than sinusoidal.
A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. Semilog labelling program can be downloaded at hager.se. Earth fault breaker with soft leads can be connected under phase rail with screw connectors. The phase rail is simply pressed into place; you need never re-tighten. NOTE: Hager’s KDNxxx phase rail must be used.
Earth fault breaker 2-pole type A
Hager
Earth fault breaker 2-pole type A
Art. no.: 2163652
Earth fault breakers are used as personal or installation protection for conduction to earth that is greater than 10, 30 or 300 mA. All earth fault breakers are surge-proof, which means that they are protected against unnecessary disconnections from electric mains due to transients or what we call spikes. All earth fault breakers type A are DC pulse sensitive and can thus break the main circuit in the event of fault currents other than sinusoidal. A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. The Semiolog marking program can be downloaded at Hager.se
Earth fault breaker 5SV3 2-pole
Siemens
Earth fault breaker 5SV3 2-pole
Art. no.: 2167736
An earth fault breaker is used as a supplementary protection to prevent personal injury and fires caused by an electric overload through insulation errors, damage or unintentional contact. For personal protection, and earth fault breaker is used with 10 or 30 mA error current sensitivity and for fire protection, and earth fault breaker with max 300 mA error current sensitivity is used. Earth fault breaker type A can handle detecting both alternating current and pulsating direct current errors. Each earth fault breaker must have its own neutral base/neutral bar, and neutral must be separated from the protective conductor. Earth fault breaker is connected upstream of the group or electrical apparatus to be protected. The earth fault breaker’s must be checked frequently with the test button that is on every earth fault breaker. When the test button is pressed, a fault current is simulated and the earth fault breaker must trigger.
Earth fault breaker 5SV3 4-pole
Siemens
Earth fault breaker 5SV3 4-pole
Art. no.: 2167740
An earth fault breaker is used as a supplementary protection to prevent personal injury and fires caused by an electric overload through insulation errors, damage or unintentional contact. For personal protection, and earth fault breaker is used with 10 or 30 mA error current sensitivity and for fire protection, and earth fault breaker with max 300 mA error current sensitivity is used. Earth fault breaker type A can handle detecting both alternating current and pulsating direct current errors. Each earth fault breaker must have its own neutral base/neutral bar, and neutral must be separated from the protective conductor. Earth fault breaker is connected upstream of the group or electrical apparatus to be protected. The earth fault breaker’s must be checked frequently with the test button that is on every earth fault breaker. When the test button is pressed, a fault current is simulated and the earth fault breaker must trigger.