21 Standard components

Do you need fuses? Ahlsell helps you find installation material for all your electrical jobs. Whether you work with commercial properties or private residences, we have the range for your next project. We offer products from several well-known suppliers. Here you will find wall sockets, cable ladders, and accessories for easy installations. We also offer smart wall sockets, switches, and dimmers from several major suppliers. Modern products for modern solutions. All the installation material you need under one roof. A job well done begins with good materials. Explore our wide range of fuses, installation materials, and accessories here in the online store or visit your nearest Ahlsell shop.

Bygg din elcentral och strömställare med drag and drop-funktion med Schneider Electric eDesign
Products (238)
Earth fault breaker 5SV3 4-pole
Siemens
Earth fault breaker 5SV3 4-pole
Art. no.: 2167740
An earth fault breaker is used as a supplementary protection to prevent personal injury and fires caused by an electric overload through insulation errors, damage or unintentional contact. For personal protection, and earth fault breaker is used with 10 or 30 mA error current sensitivity and for fire protection, and earth fault breaker with max 300 mA error current sensitivity is used. Earth fault breaker type A can handle detecting both alternating current and pulsating direct current errors. Each earth fault breaker must have its own neutral base/neutral bar, and neutral must be separated from the protective conductor. Earth fault breaker is connected upstream of the group or electrical apparatus to be protected. The earth fault breaker’s must be checked frequently with the test button that is on every earth fault breaker. When the test button is pressed, a fault current is simulated and the earth fault breaker must trigger.
Earth fault breaker 2-pole type A, Quick Connect
Hager
Earth fault breaker 2-pole type A, Quick Connect
Art. no.: 2163812
Earth fault breakers are used as personal or installation protection for conduction to earth that is greater than 10, 30 or 300 mA. All earth fault breakers are surge-proof, which means that they are protected against unnecessary disconnections from electric mains due to transients or what we call spikes. All earth fault breakers type A are DC pulse sensitive and can thus break the main circuit in the event of fault currents other than sinusoidal. A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. Semilog labelling program can be downloaded at hager.se. Earth fault breaker with soft leads can be connected under phase rail with screw connectors. The phase rail is simply pressed into place; you need never re-tighten. NOTE: Hager’s KDNxxx phase rail must be used.
Earth fault breaker 2-pole type A, Quick Connect
Miniature circuit breaker 3-pole type D 10kA
Hager
Miniature circuit breaker 3-pole type D 10kA
Art. no.: 2107309
Miniature circuit breaker 3 pole type D 10kA for industry, offices or where high short-circuit currents exist. For reliable protection of cables and conductors against overload and short circuit.
For devices with very high starting currents e.g. motors and transformers. Accessories like auxiliary contacts, signal contacts, shunt release and under-voltage trigger are mounted without tools on the miniature circuit breaker. DIN rail bracket’s advanced attachment mechanism means you can easily disconnect products from the DIN rail. All miniature circuit breakers meet the requirements of IEC/EN 60898 and IEC/EN 60947-2 standards. All conductive parts are tamper-proof, easy removal from the phase rail - with new DIN rail clips, one on top and on at bottom. Pure and simple labelling – a transparent protective for labelling area
Miniature circuit breaker 3-pole type D 10kAMiniature circuit breaker 3-pole type D 10kAMiniature circuit breaker 3-pole type D 10kAMiniature circuit breaker 3-pole type D 10kAMiniature circuit breaker 3-pole type D 10kA
Earth fault breaker 4-pole type A Quick Connect
Hager
Earth fault breaker 4-pole type A Quick Connect
Art. no.: 2163820
Earth fault breakers are used as personal or installation protection for conduction to earth that is greater than 10, 30 or 300 mA. All earth fault breakers are surge-proof, which means that they are protected against unnecessary disconnections from electric mains due to transients or what we call spikes. All earth fault breakers type A are DC pulse sensitive and can thus break the main circuit in the event of fault currents other than sinusoidal.
A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail. A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. Semilog labelling program can be downloaded at hager.se. Earth fault breaker with soft leads can be connected under phase rail with screw connectors. The phase rail is simply pressed into place; you need never re-tighten. NOTE: Hager’s KDNxxx phase rail must be used.
Earth fault breaker 4-pole type A Quick ConnectEarth fault breaker 4-pole type A Quick ConnectEarth fault breaker 4-pole type A Quick Connect
Residual current circuit breaker with overcurrent protection 4-pole type C, ADM, Hager
Hager
Residual current circuit breaker with overcurrent protection 4-pole type C, ADM, Hager
Art. no.: 2163672
An RCBO is an RCD with built-in over-current protection in an MCB, which saves space and makes things easier to see. An RCBO is an RCD with built-in over-current protection in an MCB. The RCBOs are of type A, for AC and pulsing DC residual current, and with the neutral on the right. Choose between B and C characteristics, 30 mA for protection against injury. Surge-proof, minimum temperature -25ºC and breaking capacity 6 kA
A new DIN rail bracket with an advanced attachment mechanism means you can easily disconnect products from the DIN rail.
A transparent protective cover for the marking areas on Hager’s new-generation modular components. To open and apply the marking strip, simply press the lower edge. The Semiolog marking program can be downloaded at Hager.se
RCDs with soft leads can be connected under the phase rail with screw connectors.
The phase rail is simply pressed into place; you need never re-tighten.
NOTE: Hager’s KDNxxx phase rail must be used.
Residual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, HagerResidual current circuit breaker with overcurrent protection 4-pole type C, ADM, Hager
Residual current circuit breakers iDPN Vigi
Schneider Electric
Residual current circuit breakers iDPN Vigi
Art. no.: 2164986
iDPN Vigi, a combination of 1-pole miniature circuit breaker and earth fault protection with 2 modules’ width (36 mm), is of electromechanical type and works without external voltage sources. They are available in B- and C-curve in AC and A class as well as in Asi design, i.e. short-time delayed with elevated power surge resistance and breaking capacity 6kA or respectively 10kA. iDPN Vigi can be supplied with help functions for indication (help/signal contact) and remote tripping (shunt/undervoltage trigger), the same accessories as inC60 are used in addition to OF and SD, where A9A26924 (OF) and A9A26927 (SD) are to be used. Since the device has two connections with 9 mm space, there are special phase rails for this series (21505,21507,21093). Connections: tunnel connections up to 10 mm².
Earth fault breaker 5SV3 2-pole
Siemens
Earth fault breaker 5SV3 2-pole
Art. no.: 2167736
An earth fault breaker is used as a supplementary protection to prevent personal injury and fires caused by an electric overload through insulation errors, damage or unintentional contact. For personal protection, and earth fault breaker is used with 10 or 30 mA error current sensitivity and for fire protection, and earth fault breaker with max 300 mA error current sensitivity is used. Earth fault breaker type A can handle detecting both alternating current and pulsating direct current errors. Each earth fault breaker must have its own neutral base/neutral bar, and neutral must be separated from the protective conductor. Earth fault breaker is connected upstream of the group or electrical apparatus to be protected. The earth fault breaker’s must be checked frequently with the test button that is on every earth fault breaker. When the test button is pressed, a fault current is simulated and the earth fault breaker must trigger.
Earth fault breaker 5SV3 4-pole, with neutral to left
Siemens
Earth fault breaker 5SV3 4-pole, with neutral to left
Art. no.: 2167805
An earth fault breaker is used as a supplementary protection to prevent personal injury and fires caused by an electric overload through insulation errors, damage or unintentional contact. For personal protection, and earth fault breaker is used with 10 or 30 mA error current sensitivity and for fire protection, and earth fault breaker with max 300 mA error current sensitivity is used. Earth fault breaker type A can handle detecting both alternating current and pulsating direct current errors. Each earth fault breaker must have its own neutral base/neutral bar, and neutral must be separated from the protective conductor. Earth fault breaker is connected upstream of the group or electrical apparatus to be protected. The earth fault breaker’s must be checked frequently with the test button that is on every earth fault breaker. When the test button is pressed, a fault current is simulated and the earth fault breaker must trigger.
Showing 52 of 238