Feedback



Fluke
Multimeter 83V/87V
FLUKE 87-5 0
Article number: Suppl. article no:
4203225
3947858
to see price and stock
General specifications:
Maximum voltage between terminal and ground: 1000 V rms
Fuse protection for mA or µA inputs: 44/100 A, 1000 V FAST Fuse
Fuse protection for A input: 11 A, 1000 V FAST Fuse
Show:
Digital: 6000 counts updates 4 / sec; (Model 87V also has 19,999 bills in high resolution mode)
Analog: 33 segments, updates 40 / sec.
Frequency: 19,999 counts, updates 3 / sec at >10 Hz
Temperature: Operation: -20 ° C to +55 ° C; Storage: -40 ° C to +60 ° C
Altitude:
Operation: 2000 m
Storage: 10,000 m
Temperature coefficient: 0.05 x (specified accuracy) / ° C ( 28 ° C)
Electromagnetic compatibility: In an RF field with 3 V / m total accuracy = specified accuracy
Relative humidity: 0% to 90% (0 ° C to 35 ° C); 0% to 70% (35 ° C to 55 ° C)
Battery type: 9 V zinc, NEDA 1604 or 6F22 or 006P
Battery life: 400 hours typically with alkaline (with backlight off)
Vibration: Per MIL-PRF-28800 for a Class 2 instrument
Shock: 1 meter drop per IEC 61010-1: 2001
Size (HxWxL): 1.25 x x 3.41 in x 7.35 inches (3.1 cm x 8.6 cm x 18.6 cm)
Size with holster and flex stand: 2.06 in x 3.86 in x 7.93 inches (5.2 cm x 9.8 cm x 20.1 cm)
Weight: 355 g (12.5 oz)
Weight with holster and flex stand: 624 g (22.0 oz)
Safety: Meets ANSI / ISA S82.01-2004, CSA 22.2 no 1010.1: 2004 to 1000 V surge voltage category
Maximum voltage between terminal and ground: 1000 V rms
Fuse protection for mA or µA inputs: 44/100 A, 1000 V FAST Fuse
Fuse protection for A input: 11 A, 1000 V FAST Fuse
Show:
Digital: 6000 counts updates 4 / sec; (Model 87V also has 19,999 bills in high resolution mode)
Analog: 33 segments, updates 40 / sec.
Frequency: 19,999 counts, updates 3 / sec at >10 Hz
Temperature: Operation: -20 ° C to +55 ° C; Storage: -40 ° C to +60 ° C
Altitude:
Operation: 2000 m
Storage: 10,000 m
Temperature coefficient: 0.05 x (specified accuracy) / ° C ( 28 ° C)
Electromagnetic compatibility: In an RF field with 3 V / m total accuracy = specified accuracy
Relative humidity: 0% to 90% (0 ° C to 35 ° C); 0% to 70% (35 ° C to 55 ° C)
Battery type: 9 V zinc, NEDA 1604 or 6F22 or 006P
Battery life: 400 hours typically with alkaline (with backlight off)
Vibration: Per MIL-PRF-28800 for a Class 2 instrument
Shock: 1 meter drop per IEC 61010-1: 2001
Size (HxWxL): 1.25 x x 3.41 in x 7.35 inches (3.1 cm x 8.6 cm x 18.6 cm)
Size with holster and flex stand: 2.06 in x 3.86 in x 7.93 inches (5.2 cm x 9.8 cm x 20.1 cm)
Weight: 355 g (12.5 oz)
Weight with holster and flex stand: 624 g (22.0 oz)
Safety: Meets ANSI / ISA S82.01-2004, CSA 22.2 no 1010.1: 2004 to 1000 V surge voltage category
- Article number: 4203225
- Suppl. article no: 3947858
- Ean no: 0095969586733
- Replaces art.nbr: 4203232
- Material class QF2300
Technical data
- Packagin Size: 1 ST/5 ST
- Type: 87V
- Max. voltage measuring range AC: 1000 V
- Max. current measuring range, AC: 10 A
- Max. current measuring range, DC: 10 A
- Frequency measurement: TRUE
- Interface: FALSE
- Indication: Digital
- Inductance measurement: FALSE
- Capacitance measurement: TRUE
- With conductivity measurement: TRUE
- Lowest resolution, DC voltage: 0.01 mV
- Lowest resolution, DC current: 0.01 µA
- Lowest resolution, resistance: 0.01 Ohm
- Lowest resolution, AC voltage: 0.01 mV
- Lowest resolution, AC current: 0.01 µA
- Max. resistance measuring range: 50 MOhm
- With decibel measurement (dB): FALSE
- Data hold: TRUE
- Multiple display: FALSE
- Measuring circuit category: CAT IV
- Measuring range selection: Manual/automatic
- Duty cycle measurements: TRUE
- Relative value measurement: TRUE
- Resistance test/diode test: TRUE
- Peak value memory: TRUE
- True RMS measurement: TRUE
- Harmonics analysis/power quality: FALSE
- Automatic circuit breaker: FALSE
- Bluetooth interface: FALSE
- Power and energy measurement: FALSE
- Explosion-tested version: FALSE
- IR interface: FALSE
- Cable length measurement: FALSE
- Cable symmetry testing for two wire connections a-b-E: FALSE
- Continuity test: TRUE
- Lowest resolution, frequency: 0.01 Hz
- Lowest resolution, capacitance: 0.00001 µF
- Lowest resolution temperature: 0.1 °C
- Max. frequency measuring range: 200 kHz
- Max. capacitance measuring range: 9999 µF
- Max. voltage measuring circuit category: 600 V
- Milliohm measurement with 4 wire technique (Kelvin connection): FALSE
- Nominal test voltage 100 V: FALSE
- Nominal test voltage 1000 V: FALSE
- Nominal test voltage 250 V: FALSE
- Nominal test voltage 500 V: FALSE
- Nominal test voltage 10 V: FALSE
- Nominal test voltage 50 V: FALSE
- Rotational speed measuring: FALSE
- Temperature measurement RTD: FALSE
- Temperature measurement TC: TRUE
- Analogue bar graph display: TRUE
- Measured value memory: FALSE
- Max. voltage measuring range DC: 1000 V
- Max. value storage: TRUE
- Min. value storage: TRUE