Time relay, standard

Do you work with electrical service and automation in properties or workshops? Ahlsell helps you find the right products for you. Whether you work with commercial properties or private residences, we have the range for your needs. Here you will find contractors, buttons, sensors, safety switches, and accessories for easy installation. Learn more about our products here or visit your nearest Ahlsell store.

Products (11)
Timer relay a-collection
a-collection
Timer relay a-collection
Art. no.: 4098560
Function Op, operation delayed: Time calculation starts when the contact on the active input is closed. After the set time the relay switches on regardless of whether the contact on the active input is closed or open. If the contact is closed again after the time calculation has been switched off, the relay turns off and the time calculation starts again.
Function in, delayed disconnection: Time calculation starts and the relay opens when the contact on the active input is closed. After the set time the relay switches off regardless of whether the contact on the active input is closed or open. If the contact is closed again after the time calculation has been completed, the relay turns on and the time calculation starts again.
Function Dr, drop out delayed: The relay opens when the contact on the activation input is closed. When the contact is broken the time calculation starts. After the set time, the relay turns off. If the contact on the active input is closed while the time calculation is being made, the time calculation is reset while the relay is still turned on.
Flashing Function - Function R: (ON time first), (Function, Rb, OFF time first). When the control voltage is connected, the time starts to be calculated, when the period has expired the relay disengages. When the time for the disengaged relay has expired, the relay opens. This process continues as long as the control voltage is connected. The time for the rest and running time is equal. All relevant data, as well as the circuit diagram are clearly marked on the side of the relays.
Indication: 2 LEDs. Green lights up when the control voltage is connected. Yellow lights up when the relay is closed and flashes during the time calculation
Timer relay Analogue DIN-mounting 18 functions
Eltako
Timer relay Analogue DIN-mounting 18 functions
Art. no.: 4082131
Multifunction relay MFZ12DX-UC 1 switching contact 10A
Multi-voltage 8-230V AC/DC
With Eltako’s Duplex technology (DX), the NO terminals, in case of 230V AC failure 50Hz, can be switched to zero crossing mode to considerably reduce wear. This is achieved by connecting the N wire to the terminal (N) and L to 15 (L). The standby consumption is only be 0.1W.
NOTE: Contactors for increasing the switch capacity should not be connected in series to this kind of device.
Resettable time between 0.1 seconds to 40 hours. Thanks to the use of bistable relay function, potential problems with coil loss effects and heat generation can be avoided, even when the relay is "ON". Wait until the short automatic synchronisation has finished after installation before connecting the connected consumers to the network. By connecting the operating voltage either at B1-A2 or B2-A2 two different functional levels are selected:
Thanks to the use of bistable relay function, potential problems with coil loss effects and heat generation can be avoided, even when the relay is "ON".Wait until the short automatic synchronisation has finished after installation before connecting the connected consumers to the network.
Multifunction relay DIN-assembly ESR12NP 16A
Eltako
Multifunction relay DIN-assembly ESR12NP 16A
Art. no.: 4003188
For rail mounting in accordance with DIN-EN 60715 TH35. With modern hybrid technology that combines the best aspects of wear-free electronic control and high-performance special relays. With multi-voltage 8 for 230V AC/DC. Extremely low noise level. Thanks to the use of bistable relay function, potential problems with coil loss effects and heat generation can be avoided, even when the relay is in operation. 2 to 120 minute switch-off delay which can be set directly in the front if the ESV function is selected. With LED indication. This flashes after 15 minutes if the button is blocked (not in ER function). Glow lamp current up to 150 mA, only on 230V- input, independent of ignition current (not in ER function). Switch-off occurs when supply voltage is cut off. The ES, ESV and ER functions can be selected directly in the front. ES = Impulse function ER = Relay function ESV = Impulse function with switch-off delay. If no new impulse comes during the countdown, the relay automatically switches when the time (can be set to up to 120 min) runs out. ESV = Switch-off warning, lamps (e.g. in stairway) start to flash approx. 30 seconds before time runs out. During this time, the time can be zeroed by pressing the button again. ESV = Constant on, the relay can be activated by holding the pushbutton for more than 1 second. They switch off automatically after 2 hours or when the button is depressed for more than 2 seconds. ESV = If both switch-off warning and constant are selected, the switch-off warning is activated before constant light is switched off.
Technical data:
Timer relay Analogue DIN-mounting 18 functions
Eltako
Timer relay Analogue DIN-mounting 18 functions
Art. no.: 4082130
MFZ12DDX-UC 1vx 10A
With Eltako’s Duplex technology (DX), the NO terminals, in case of 230V AC failure 50Hz, can be switched to zero crossing mode to considerably reduce wear. This is achieved by connecting the N wire to the terminal (N) and L to 15 (L). NOTE: Contactors for increasing the switch capacity should not be connected in series to this kind of device. Thanks to the use of bistable relay function, potential problems with coil loss effects and heat generation can be avoided, even when the relay is in operation. All values for time setting can be made with preset time ranges (0,1-9.9 or 1-99 seconds, minutes or hours). Max. delay is 99 hours. Up to 600 different settings possible. The time countdown is continually shown in the display. Reliable in case of loss of power: All settings are saved in an EEPROM memory, so they remain unchanged when the power is restored. When using the functions: TI, TP, IA, EAW, AV and ARV+, a second time can be set completely independent of the first.
Showing 11 of 11