With Eltako’s Duplex technology (DX), the NO terminals, in case of 230V AC failure 50Hz, can be switched to zero crossing mode to considerably reduce wear. This is achieved by connecting the N wire to the terminal (N) and L to 15 (L). NOTE: Contactors for increasing the switch capacity should not be connected in series to this kind of device. Thanks to the use of bistable relay function, potential problems with coil loss effects and heat generation can be avoided, even when the relay is in operation. All values for time setting can be made with preset time ranges (0,1-9.9 or 1-99 seconds, minutes or hours). Max. delay is 99 hours. Up to 600 different settings possible. The time countdown is continually shown in the display. Reliable in case of loss of power: All settings are saved in an EEPROM memory, so they remain unchanged when the power is restored. When using the functions: TI, TP, IA, EAW, AV and ARV+, a second time can be set completely independent of the first.
With Eltako’s Duplex technology (DX), the NO terminals, in case of 230V AC failure 50Hz, can be switched to zero crossing mode to considerably reduce wear. This is achieved by connecting the N wire to the terminal (N) and L to 15 (L). NOTE: Contactors for increasing the switch capacity should not be connected in series to this kind of device. Thanks to the use of bistable relay function, potential problems with coil loss effects and heat generation can be avoided, even when the relay is in operation. All values for time setting can be made with preset time ranges (0,1-9.9 or 1-99 seconds, minutes or hours). Max. delay is 99 hours. Up to 600 different settings possible. The time countdown is continually shown in the display. Reliable in case of loss of power: All settings are saved in an EEPROM memory, so they remain unchanged when the power is restored. When using the functions: TI, TP, IA, EAW, AV and ARV+, a second time can be set completely independent of the first.
- Article number: 4082130
- Suppl. article no: MFZ12DDX-UC
- Ean no: 4010312603079
- Material class QP510A
Technical data
- Packagin Size: 1 PCS/10 PCS/100 PCS
- Type: MFZ12DDX-UC
- Width in number of modular spacings: 1
- Switch capacity fluorescent lamp parallel: 500 VA
- Switch capacity incandescent lamps: 2000 W
- Switch capacity fluorescent lamp DUO: 1000 VA
- Switch capacity fluorescent lamp inductive: 1000 VA
- Type of excitation: Digital with multi function
- 1st interval: 1-99
- 2nd interval: 0.1-99
- Number of changeover switches: 1
- Control voltage 1: 8-230 V
- Nominal switching current at 250 V AC: 10 A
- REACH Date: 2021-01-01
- Frequency control voltage 1: 0-60 Hz
- Built-in height: 58 mm
- Supply voltage: 8-230 V
- Function: Multi function
- Voltage type (supply voltage): AC/DC
- REACH Information obligation: No
- Type of control voltage 1: AC/DC
- 1st interval unit: Seconds/minutes
- 2nd interval unit: Minutes/hours
- Mounting method: DIN rail