Feedback

Connection cable RQ (H07Z1-K) 450/750V ≥4.0mm² Dca - RQ 35 450/750V BLACK (*0)
Nexans

Connection cable RQ (H07Z1-K) 450/750V ≥4.0mm² Dca

RQ 35 450/750V BLACK (*0)
Article number: 
0369700
Suppl. article no: 
11195898-801-00





 to see price and stock
Third party verified Environmental product declaration
The cable is primarily intended to be used for internal connections in junction cabinets or the like. RQ is a halogen-free, HFFR-insulated, coupling line with a round multi-stranded copper conductor. The cable is constructed according to SS 424 02 31-3 in applicable parts. The conductor has resistance according to IEC 60228 class 5. The insulation is marked "NEXANS GS Z1 SEMKO AREA mm2" or "NEXANS GS SEMKO area mm² HALOGEN FREE". RQ meets fire spread class D. The cable is approved by SEMKO.
  • Article number: 
    0369700
  • Suppl. article no: 
    11195898-801-00
  • Ean no: 
    7330000083530
  • Replaces art.nbr: 
    0366320
  • Material class 
    QA4800
Technical data
  • Packagin Size: 1 M/500 M
  • Cable type: RQ
  • Dimension conductor x area: 35 mm²
  • Core colour: Black
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Outer diameter approximate: 9.9 mm
  • Nominal voltage U0: 450 V
  • Nominal voltage U: 750 V
  • Conductor category: Class 5 = flexible
  • Conductor material: Copper
  • Diameter conductor: 10 mm
  • Shape of conductor: Round
  • Max. permitted conductor temperature: 70 °C
  • Armouring/reinforcement: None
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Screen: No
  • Material core insulation: Polyolefin
  • Conductor resistance at 20 °C: 0.554 Ohm/km
  • Core identification: Colour
  • Core identification according to HD 308 S2: Yes
  • Nominal cross section conductor: 35 mm²
  • Conductor surface: Bare
  • Number of cores: 1
  • Cable geometry: Round
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Drain wire: No
  • Weight: 330 kg/km
  • Low temperature resistant according to EN 60811-504+505+506: Yes
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Min. permitted bending radius, stationary application/permanent installation: 39.6 mm
  • Permitted cable outer temperature during assembling/handling: -10-50 °C
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Certified for shipboard application: No
  • Certified as airport lighting cable: No
  • Suitable as installation cable: Yes
  • Protective barrier: None
  • REACH Date: 2021-06-14
  • GWP-tot (A1-A3): 0,9105 kgCO2e/M
  • REACH Information obligation: No