Feedback

Connecting cable for solar panels H1Z2Z2-K Dca Optimized version, Patch - SOLAR H1Z2Z2-K OPTIM 4 BK 1023759
Miltronic

Connecting cable for solar panels H1Z2Z2-K Dca Optimized version, Patch

SOLAR H1Z2Z2-K OPTIM 4 BK 1023759
Article number: 
0523390
Suppl. article no: 
1023759





 to see price and stock
Double-insulated tinned single conductor which is intended to connect solar cell modules to each other and as a connection between the solar cell modules and the DC / AC converter. For rated voltage 1.0 kV AC or 1.5 (1.8) kV DC
It is certified according to EN standard 50618, which among other things guarantees mechanical strength, weather, UV and ozone resistance. Can be placed in ground pipes. It is halogen-free and otherwise has good fire properties. CPR class Dca-s2-d2-a1. Available with black, red or blue outer shell. Meter marked.
  • Article number: 
    0523390
  • Suppl. article no: 
    1023759
  • Ean no: 
    4056155097880
  • Material class 
    QA5700
  • This is an alternative to item  
    0516760
Technical data
  • Packagin Size: 1 M/500 M
  • Dimension conductor x area: 4 mm²
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Colour outer sheath: Black
  • With protective conductor: No
  • Screen over stranding element: None
  • Screen over stranding: None
  • Outer diameter approximate: 5.5 mm
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Shape of conductor: Round
  • Cable geometry: Round
  • Conductor category: Class 5 = flexible
  • Permitted cable outer temperature after assembling without vibration: -40-120 °C
  • Permitted cable outer temperature during assembling/handling: -25-90 °C
  • Material outer sheath: Polyolefin
  • Material core insulation: Polyolefin
  • Low temperature resistant according to EN 60811-504+505+506: Yes
  • Nominal voltage U: 1500 V
  • Nominal voltage U0: 1500 V
  • Oil resistant according to EN IEC 60811-404: No
  • Core identification: Colour
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Stranding element: No
  • Suspension element: None
  • Reaction-to-fire according to EN 13501-6: Acidity: a1
  • Torsion resistant: No
  • Min. permitted bending radius, stationary application/permanent installation: 22 mm
  • Specification core insulation: Other
  • Specification material outer sheath: Other
  • Weight: 60 kg/km
  • Conductor material: Copper
  • Conductor resistance at 20 °C: 5.09 Ohm/km
  • Conductor surface: Tinned
  • Core identification according to HD 308 S2: No
  • Armouring/reinforcement: None
  • Drain wire: No
  • Max. permitted conductor temperature: 120 °C
  • Protective barrier: None
  • Screen: No
  • Flame retardant according to IEC 60332-1-2: Yes
  • Halogen free according to EN IEC 60754-1: Yes
  • Halogen free according to EN IEC 60754-2: Yes
  • Low smoke according to EN IEC 61034-2: Yes
  • Nominal cross section conductor: 4 mm²
  • Number of cores: 1
  • REACH Date: 2023-06-16
  • REACH Information obligation: No