Feedback
The cable is intended for fixed installation indoors and outdoors for control signals in electronic equipment. It has an aluminum screen.
FQAR-G is a halogen-free, PEX-insulated, aluminum-shielded and HFFR-coated control cable with round wired copper conductor conductors. The cable is provided with a tear thread to simplify scaling. The cable is designed according to SS 424 03 21 in applicable parts. The conductor has thread count and resistance according to IEC 60228 class 2. The parties are number marked according to SS 424 17 20. The jacket is marked type / manufacturer / year + month / meter marking. FQAR-G meets fire spread class D. The cable is approved by SEMKO.
The cable is marked with Lifemark TM recycling mark (content declared).
FQAR-G is a halogen-free, PEX-insulated, aluminum-shielded and HFFR-coated control cable with round wired copper conductor conductors. The cable is provided with a tear thread to simplify scaling. The cable is designed according to SS 424 03 21 in applicable parts. The conductor has thread count and resistance according to IEC 60228 class 2. The parties are number marked according to SS 424 17 20. The jacket is marked type / manufacturer / year + month / meter marking. FQAR-G meets fire spread class D. The cable is approved by SEMKO.
The cable is marked with Lifemark TM recycling mark (content declared).
- Article number: 0127890
- Suppl. article no: 16214298-898-00
- Ean no: 7330000076501
- Material class QA300A
Technical data
- Cable type: FQAR-G
- Dimension conductor x area: 14x1 mm²
- Outer diameter approximate: 13 mm
- Weight/100 m: 24 kg
- Reaction-to-fire according to EN 13501-6: Class: Dca
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
- Conductor category: Class 2 = stranded
- Colour outer sheath: Grey
- Permitted cable outer temperature after assembling without vibration: -40-70 °C
- Material outer sheath: Polyolefin
- Material core insulation: Polyolefin
- Low temperature resistant according to EN 60811-504+505+506: Yes
- Nominal voltage U: 250 V
- Nominal voltage U0: 150 V
- Core identification: Numbers
- Reaction-to-fire according to EN 13501-6: Smoke production: s2
- Reaction-to-fire according to EN 13501-6: Acidity: a2
- Min. permitted bending radius, stationary application/permanent installation: 104 mm
- Halogen free according to EN IEC 60754-1: Yes
- Halogen free according to EN IEC 60754-2: Yes
- Number of cores: 14
- Nominal cross section conductor: 1 mm²
- REACH Date: 2021-06-14
- GWP-tot (A1-A3): 0,9071 kgCO2e/M
- REACH Information obligation: No