Feedback
Use: Halogen-free cable that gives off smoke with low smoke density and free from corrosive gases in the event of fire. Open fixed place, indoors and outdoors, in pipes, in soil and in water.
Conductor temperature: Max. 90 ° C, Short-circuit temperature: Max. 250 ° C, Placement temperature: Min. 0 ° C, Bending radius: Min. 10 x D, Tensile force: 50 N / mm² when connected directly in all conductors, however max. 20,000 N. Conductor: 16-35 mm²: Round filamentous annealed copper 50-240 mm²: Sector-shaped filamentous annealed copper Insulation: PEX, Party marking: 3-conductor: Brown, black, gray, 4-conductor: Blue, brown, black, gray Filler jacket / banding: 16-35 mm²: Halogen-free compound 50-240 mm²: Plastic band, halogen-free Concentric conductor: Annealed copper wire with counter-coil, Banding: 25-240 mm²: Plastic band, halogen-free, Sheath: Halogen-free polyolefin, Coat color: Black, Standard: SS 424 14 18, HD603 where applicable, Rated voltage: 1 kV, Test voltage: 3.5 kV, Fire rating: D, CE conformity: Low voltage directive.
Conductor temperature: Max. 90 ° C, Short-circuit temperature: Max. 250 ° C, Placement temperature: Min. 0 ° C, Bending radius: Min. 10 x D, Tensile force: 50 N / mm² when connected directly in all conductors, however max. 20,000 N. Conductor: 16-35 mm²: Round filamentous annealed copper 50-240 mm²: Sector-shaped filamentous annealed copper Insulation: PEX, Party marking: 3-conductor: Brown, black, gray, 4-conductor: Blue, brown, black, gray Filler jacket / banding: 16-35 mm²: Halogen-free compound 50-240 mm²: Plastic band, halogen-free Concentric conductor: Annealed copper wire with counter-coil, Banding: 25-240 mm²: Plastic band, halogen-free, Sheath: Halogen-free polyolefin, Coat color: Black, Standard: SS 424 14 18, HD603 where applicable, Rated voltage: 1 kV, Test voltage: 3.5 kV, Fire rating: D, CE conformity: Low voltage directive.
- Article number: 0017440
- Ean no: 7394479012309
- Replaces art.nbr: 0006240
- Material class QA070A
Technical data
- Cable type: FXQJ
- Dimension conductor x area: 3x16/16 mm²
- Reaction-to-fire according to EN 13501-6: Class: Dca
- Outer diameter approximate: 20 mm
- Nominal voltage U0: 0.6 kV
- Nominal voltage U: 1 kV
- With protective conductor: No
- Colour outer sheath: Black
- Conductor category: Class 2 = stranded
- Conductor material: Copper
- Max. permitted conductor temperature: 90 °C
- Low smoke according to EN IEC 61034-2: Yes
- Number of pilot/reduced conductors: 0
- Armouring/reinforcement: None
- Halogen free according to EN IEC 60754-2: Yes
- Reaction-to-fire according to EN 13501-6: Acidity: a2
- Screen: Yes
- Material core insulation: Other
- Core identification: Colour
- Conductive coating: No
- Specification core insulation: Crosslinked polyethylene (XLPE)
- Shape of conductor: Round
- Nominal cross section conductor: 16 mm²
- Conductor surface: Bare
- Number of cores: 3
- Cable geometry: Round
- Concentric conductor: Copper
- Nominal cross section concentric conductor: 16 mm²
- Longitudinal water blocking screen: No
- Laminated sheath: No
- Lead sheath: No
- Drain wire: No
- Weight/100 m: 84 kg
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
- Flame retardant according to IEC 60332-3-24 (Cat C): Yes
- Longitudinal water blocking conductors: No
- Reaction-to-fire according to EN 13501-6: Smoke production: s2
- Inner semi-conducting layer: No
- Material outer sheath: Polyolefin
- Outer semi-conducting layer: No
- Fibre optic elements: No
- REACH Date: 2021-12-09
- REACH Information obligation: No