Low voltage FXQJ 1kV Dca, Nkt - FXQJ 3X16/16 (*5)
NKT

Low voltage FXQJ 1kV Dca, Nkt

FXQJ 3X16/16 (*5)
Article number: 
0017440





 to see price and stock
Third party verified Environmental product declarationProdukten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.
Use: Halogen-free cable that gives off smoke with low smoke density and free from corrosive gases in the event of fire. Open fixed place, indoors and outdoors, in pipes, in soil and in water.

Conductor temperature: Max. 90 ° C, Short-circuit temperature: Max. 250 ° C, Placement temperature: Min. 0 ° C, Bending radius: Min. 10 x D, Tensile force: 50 N / mm² when connected directly in all conductors, however max. 20,000 N. Conductor: 16-35 mm²: Round filamentous annealed copper 50-240 mm²: Sector-shaped filamentous annealed copper Insulation: PEX, Party marking: 3-conductor: Brown, black, gray, 4-conductor: Blue, brown, black, gray Filler jacket / banding: 16-35 mm²: Halogen-free compound 50-240 mm²: Plastic band, halogen-free Concentric conductor: Annealed copper wire with counter-coil, Banding: 25-240 mm²: Plastic band, halogen-free, Sheath: Halogen-free polyolefin, Coat color: Black, Standard: SS 424 14 18, HD603 where applicable, Rated voltage: 1 kV, Test voltage: 3.5 kV, Fire rating: D, CE conformity: Low voltage directive.
  • Article number: 
    0017440
  • Ean no: 
    7394479012309
  • Replaces art.nbr: 
    0006240
  • Material class 
    QA070A
Technical data
  • Cable type: FXQJ
  • Dimension conductor x area: 3x16/16 mm²
  • Outer diameter approximate: 20 mm
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Colour outer sheath: Black
  • Weight/100 m: 84 kg
  • Nominal voltage U: 1 kV
  • Nominal voltage U0: 0.6 kV
  • Conductor category: Class 2 = stranded
  • Conductor material: Copper
  • Halogen free according to EN IEC 60754-2: Yes
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Shape of conductor: Round
  • Number of pilot/reduced conductors: 0
  • Screen: Yes
  • Drain wire: No
  • Lead sheath: No
  • Concentric conductor: Copper
  • Material outer sheath: Polyolefin
  • Nominal cross section concentric conductor: 16 mm²
  • Core identification: Colour
  • With protective conductor: No
  • Material core insulation: Other
  • Max. permitted conductor temperature: 90 °C
  • Fibre optic elements: No
  • Inner semi-conducting layer: No
  • Laminated sheath: No
  • Conductive coating: No
  • Conductor surface: Bare
  • Longitudinal water blocking screen: No
  • Longitudinal water blocking conductors: No
  • Low smoke according to EN IEC 61034-2: Yes
  • Outer semi-conducting layer: No
  • Cable geometry: Round
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • Armouring/reinforcement: None
  • Flame retardant according to IEC 60332-3-24 (Cat C): Yes
  • Number of cores: 3
  • Nominal cross section conductor: 16 mm²
  • Insulation integrity: None
  • REACH Date: 2021-12-09
  • REACH Information obligation: No