Nexans

Loe voltage FXQJ EMC kV Dca, Nexans

FXQJ EMC 3X16/16 1KV BL (*5)
Article number: 
0054030
Suppl. article no: 
15141998-201-00





 to see price and stock
Third party verified Environmental product declarationProdukten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.
The cable is intended for fixed installation indoors and outdoors in air, soil and water and is suitable for industrial installations and other installations that have EMC requirements. FXQJ is a halogen-free, PEX-insulated and HFFR-coated cable with round copper wires of copper for areas up to 35 mm2. Other areas have few sector-shaped copper conductors. FXQJ is constructed in accordance with SS 424 14 18 The cable has a shield of annealed copper wire with counter-coil of solid copper strip. The conductors have thread count and resistance according to IEC 60228 class 2. The parties are color marked according to SS 424 17 20. The cable has a sprayed filling. The mantle is labeled type / manufacturer / year + month / meter marking. FXQJ meets fire spread class D. The cable is approved by SEMKO. The cable is marked with Lifemark TM recycling mark (content declared).
  • Article number: 
    0054030
  • Suppl. article no: 
    15141998-201-00
  • Ean no: 
    7330000076709
  • Replaces art.nbr: 
    0013040
  • Material class 
    QA0200
Technical data
  • Cable type: FXQJ EMC
  • Dimension conductor x area: 3x16/16 mm²
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Outer diameter approximate: 21 mm
  • Nominal voltage U0: 0.6 kV
  • Nominal voltage U: 1 kV
  • With protective conductor: Yes
  • Colour outer sheath: Black
  • Conductor category: Class 2 = stranded
  • Conductor material: Copper
  • Max. permitted conductor temperature: 90 °C
  • Low smoke according to EN IEC 61034-2: Yes
  • Armouring/reinforcement: None
  • Halogen free according to EN IEC 60754-1: Yes
  • Halogen free according to EN IEC 60754-2: Yes
  • Halogen free according to EN IEC 60754-3: Yes
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Screen: Yes
  • Material core insulation: Other
  • Conductor resistance at 20 °C: 1.15 Ohm/km
  • Core identification: Colour
  • Conductive coating: No
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • Core identification according to HD 308 S2: Yes
  • Shape of conductor: Round
  • Nominal cross section conductor: 16 mm²
  • Conductor surface: Bare
  • Number of cores: 4
  • Cable geometry: Round
  • Concentric conductor: Copper
  • Nominal cross section concentric conductor: 16 mm²
  • Longitudinal water blocking screen: No
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Laminated sheath: No
  • Lead sheath: No
  • Drain wire: No
  • Suitable for underground installation: Yes
  • Max. tensile strength during installation: 2.4 kN
  • Weight: 872 kg/km
  • Weight/100 m: 93 kg
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Min. permitted bending radius, stationary application/permanent installation: 168 mm
  • Longitudinal water blocking conductors: No
  • Radial water blocking cable: No
  • Permitted cable outer temperature during assembling/handling: -10-50 °C
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Certified for shipboard application: No
  • Certified as airport lighting cable: No
  • Inner semi-conducting layer: No
  • Suitable as installation cable: Yes
  • Material outer sheath: Polyolefin
  • Outer semi-conducting layer: No
  • UV resistant: Yes
  • Fibre optic elements: No
  • Oil resistant according to EN IEC 60811-404: Yes
  • REACH Date: 2021-06-14
  • GWP-tot (A1-A3): 2,0216 kgCO2e/M
  • REACH Information obligation: No