Feedback

Ground cable FXQJ EMC Dca, NKT - FXQJ EMC 3x35/16
NKT

Ground cable FXQJ EMC Dca, NKT

FXQJ EMC 3x35/16
Article number: 
0018055
Suppl. article no: 
112726006D0500





 to see price and stock
Produkten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.
Halogen-free cable that in case of fire emits smoke with low smoke density and free from corrosive gases. Fixed installation, indoors and outdoors, in pipes and in soil/water.
  • Article number: 
    0018055
  • Suppl. article no: 
    112726006D0500
  • Ean no: 
    7394479021851
  • Material class 
    QA0750
Technical data
  • Packagin Size: 500 M
  • Cable type: FXQJ
  • Dimension conductor x area: 3x35/16 mm²
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Outer diameter approximate: 22.52 mm
  • Nominal voltage U0: 0.6 kV
  • Nominal voltage U: 1 kV
  • With protective conductor: No
  • Colour outer sheath: Black
  • Conductor category: Class 2 = stranded
  • Conductor material: Copper
  • Max. permitted conductor temperature: 90 °C
  • Low smoke according to EN IEC 61034-2: Yes
  • Halogen free according to EN IEC 60754-2: Yes
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Screen: Yes
  • Material core insulation: Polyolefin
  • Conductor resistance at 20 °C: 0.524 Ohm/km
  • Core identification: Colour
  • Conductive coating: No
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • Core identification according to HD 308 S2: Yes
  • Shape of conductor: Round
  • Nominal cross section conductor: 35 mm²
  • Conductor surface: Bare
  • Number of cores: 3
  • Cable geometry: Round
  • Concentric conductor: Copper
  • Nominal cross section concentric conductor: 16 mm²
  • Longitudinal water blocking screen: No
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Laminated sheath: No
  • Lead sheath: No
  • Drain wire: No
  • Weight: 1309 kg/km
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Min. permitted bending radius, stationary application/permanent installation: 180 mm
  • Longitudinal water blocking conductors: No
  • Permitted cable outer temperature during assembling/handling: -20-70 °C
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Certified for shipboard application: No
  • Certified as airport lighting cable: No
  • Inner semi-conducting layer: No
  • Suitable as installation cable: No
  • Suitable as medium-voltage cable: No
  • Suitable as high-voltage cable: No
  • Material outer sheath: Polyolefin
  • Specification material outer sheath: Other
  • Outer semi-conducting layer: No
  • Fibre optic elements: No
  • REACH Date: 2023-07-03
  • REACH Information obligation: No