Feedback

Low voltage FXQJ 1kV Dca, Nexans - FXQJ 4X16/16 1KV (*5*0J)=JUMBO (1000m)
Nexans

Low voltage FXQJ 1kV Dca, Nexans

FXQJ 4X16/16 1KV (*5*0J)=JUMBO (1000m)
Article number: 
0014400
Suppl. article no: 
15133598-201-00





 to see price and stock
Third party verified Environmental product declarationProdukten är bedömd hos Byggvarubedömningen med totalbedömningen Accepteras.
The cable is intended for fixed installation indoors and outdoors in air, soil and water. FXQJ is a halogen-free, PEX-insulated and HFFR-coated cable with round copper wires of copper for areas up to and including 35 mm2. Other areas have few sector-shaped copper conductors. The cable has a shield of annealed copper wire with counter-coil. FXQJ is constructed in accordance with SS 424 14 18. The conductors have thread number and resistance according to IEC 60228 class 2. The parties are color-labeled according to SS 424 17 20. The cable has a sprayed filling. The mantle is labeled type / manufacturer / year + month / meter marking. FXQJ meets fire spread class D. The cable is approved by SEMKO. The cable is marked with Lifemark TM recycling mark (content declared).
  • Article number: 
    0014400
  • Suppl. article no: 
    15133598-201-00
  • Ean no: 
    7330000078437
  • Replaces art.nbr: 
    0011400
  • Material class 
    QA0201
Technical data
  • Packagin Size: 1 M/1000 M
  • Cable type: FXQJ
  • Dimension conductor x area: 4x16/16 mm²
  • Outer diameter approximate: 22 mm
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Colour outer sheath: Black
  • Weight: 1080 kg/km
  • Weight/100 m: 106 kg
  • Nominal voltage U: 1 kV
  • Nominal voltage U0: 0.6 kV
  • Conductor category: Class 2 = stranded
  • Conductor material: Copper
  • Halogen free according to EN IEC 60754-2: Yes
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Shape of conductor: Round
  • Screen: Yes
  • Drain wire: No
  • Lead sheath: No
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Permitted cable outer temperature during assembling/handling: -10-50 °C
  • Concentric conductor: Copper
  • Material outer sheath: Polyolefin
  • Nominal cross section concentric conductor: 16 mm²
  • Core identification: Colour
  • With protective conductor: Yes
  • Material core insulation: Other
  • Max. permitted conductor temperature: 90 °C
  • Fibre optic elements: No
  • Inner semi-conducting layer: No
  • Laminated sheath: No
  • Conductive coating: No
  • Conductor surface: Bare
  • Longitudinal water blocking screen: No
  • Longitudinal water blocking conductors: No
  • Low smoke according to EN IEC 61034-2: Yes
  • Outer semi-conducting layer: No
  • Certified for shipboard application: No
  • Certified as airport lighting cable: No
  • Cable geometry: Round
  • Suitable as installation cable: Yes
  • Min. permitted bending radius, stationary application/permanent installation: 176 mm
  • Core identification according to HD 308 S2: Yes
  • Conductor resistance at 20 °C: 1.15 Ohm/km
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • Diameter conductor: 4.8 mm
  • Suitable for underground installation: Yes
  • Suitable as medium-voltage cable: No
  • Max. tensile strength during installation: 3.2 kN
  • Oil resistant according to EN IEC 60811-404: Yes
  • Number of cores: 4
  • UV resistant: Yes
  • Nominal cross section conductor: 16 mm²
  • Suitable as high-voltage cable: No
  • REACH Date: 2021-06-14
  • GWP-tot (A1-A3): 2,3908 kgCO2e/M
  • REACH Information obligation: No