Feedback

Low voltage FXQJ 1kV Dca, Nexans - FXQJ 4X6/6 1KV (*5)
Nexans

Low voltage FXQJ 1kV Dca, Nexans

FXQJ 4X6/6 1KV (*5)
Article number: 
0014380
Suppl. article no: 
15133398-201-00





 to see price and stock
Third party verified Environmental product declaration
The cable is intended for fixed installation indoors and outdoors in air, soil and water. FXQJ is a halogen-free, PEX-insulated and HFFR-coated cable with round copper wires of copper for areas up to and including 35 mm2. Other areas have few sector-shaped copper conductors. The cable has a shield of annealed copper wire with counter-coil. FXQJ is constructed in accordance with SS 424 14 18. The conductors have thread number and resistance according to IEC 60228 class 2. The parties are color-labeled according to SS 424 17 20. The cable has a sprayed filling. The mantle is labeled type / manufacturer / year + month / meter marking. FXQJ meets fire spread class D. The cable is approved by SEMKO. The cable is marked with Lifemark TM recycling mark (content declared).
  • Article number: 
    0014380
  • Suppl. article no: 
    15133398-201-00
  • Ean no: 
    7330000078390
  • Replaces art.nbr: 
    0011380
  • Material class 
    QA0200
Technical data
  • Cable type: FXQJ
  • Dimension conductor x area: 4x6/6 mm²
  • Reaction-to-fire according to EN 13501-6: Class: Dca
  • Outer diameter approximate: 17 mm
  • Nominal voltage U0: 0.6 kV
  • Nominal voltage U: 1 kV
  • With protective conductor: Yes
  • Colour outer sheath: Black
  • Conductor category: Class 2 = stranded
  • Conductor material: Copper
  • Max. permitted conductor temperature: 90 °C
  • Low smoke according to EN IEC 61034-2: Yes
  • Halogen free according to EN IEC 60754-2: Yes
  • Reaction-to-fire according to EN 13501-6: Acidity: a2
  • Screen: Yes
  • Material core insulation: Other
  • Conductor resistance at 20 °C: 3.08 Ohm/km
  • Core identification: Colour
  • Conductive coating: No
  • Specification core insulation: Crosslinked polyethylene (XLPE)
  • Diameter conductor: 3 mm
  • Core identification according to HD 308 S2: Yes
  • Shape of conductor: Round
  • Nominal cross section conductor: 6 mm²
  • Conductor surface: Bare
  • Number of cores: 4
  • Cable geometry: Round
  • Concentric conductor: Copper
  • Nominal cross section concentric conductor: 6 mm²
  • Longitudinal water blocking screen: No
  • Permitted cable outer temperature after assembling without vibration: -40-70 °C
  • Laminated sheath: No
  • Lead sheath: No
  • Drain wire: No
  • Suitable for underground installation: Yes
  • Max. tensile strength during installation: 1.2 kN
  • Weight: 500 kg/km
  • Weight/100 m: 54 kg
  • Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
  • Min. permitted bending radius, stationary application/permanent installation: 136 mm
  • Longitudinal water blocking conductors: No
  • Permitted cable outer temperature during assembling/handling: -10-50 °C
  • Reaction-to-fire according to EN 13501-6: Smoke production: s2
  • Certified for shipboard application: No
  • Certified as airport lighting cable: No
  • Inner semi-conducting layer: No
  • Suitable as installation cable: Yes
  • Suitable as medium-voltage cable: No
  • Suitable as high-voltage cable: No
  • Material outer sheath: Polyolefin
  • Outer semi-conducting layer: No
  • UV resistant: Yes
  • Fibre optic elements: No
  • Oil resistant according to EN IEC 60811-404: Yes
  • REACH Date: 2021-06-14
  • GWP-tot (A1-A3): 1,6596 kgCO2e/M
  • REACH Information obligation: No