Feedback
The cable is intended for permanent installation indoors and outdoors in air, ground and water. AXQ INFRA is a halogen-free, PEX-insulated and HFFR-sheathed cable with sector-shaped (50-240 mm²) or round (16-25 mm²) low-wire conductors of aluminum The cable for TNS systems has an earth conductor of annealed copper (50-240 mm²) 16-25 mm² and 50-240 for TNC systems have earth conductors and PEN conductors of aluminum.AXQ INFRA is designed according to SS 424 14 18 in conductive parts.The conductors have wire number and resistance according to IEC 60228 class 2. The jacket is marked type / manufacturer / year + month / meter marking.The cable jacket is made of halogen-free flame-retardant material and meets fire class according to CPR class E. In case of fire, the cable emits no corrosive gases and has a slight smoke development.
AXQ INFRA is manufactured and tested in accordance with SS 424 14 18 in applicable parts. The cable may be loaded in accordance with SS 424 14 24. The cable type is approved by Intertek SEMKO. Persistent marking on the outer sheath of the cable. Lifemark: The label specifies the included plastic qualities and prepares for future recycling of the cable. AXQ INFRA replaces SE-N1XV-AS and AXQ Easy.
AXQ INFRA is manufactured and tested in accordance with SS 424 14 18 in applicable parts. The cable may be loaded in accordance with SS 424 14 24. The cable type is approved by Intertek SEMKO. Persistent marking on the outer sheath of the cable. Lifemark: The label specifies the included plastic qualities and prepares for future recycling of the cable. AXQ INFRA replaces SE-N1XV-AS and AXQ Easy.
- Article number: 0013840
- Suppl. article no: 15027398-201-00
- Ean no: 7330000083394
- Material class QA130A
Technical data
- Cable type: AXQ INFRA
- Dimension conductor x area: 4x95/29 mm²
- Reaction-to-fire according to EN 13501-6: Class: Eca
- Outer diameter approximate: 34 mm
- Nominal voltage U0: 0.6 kV
- Nominal voltage U: 1 kV
- With protective conductor: Yes
- Colour outer sheath: Black
- Conductor category: Class 2 = stranded
- Conductor material: Aluminium
- Max. permitted conductor temperature: 90 °C
- Low smoke according to EN IEC 61034-2: Yes
- Number of pilot/reduced conductors: 1
- Armouring/reinforcement: None
- Halogen free according to EN IEC 60754-2: Yes
- Reaction-to-fire according to EN 13501-6: Acidity: None
- Conductor resistance at 20 °C: 0.32 Ohm/km
- Core identification: Colour
- Conductive coating: No
- Specification core insulation: Crosslinked polyethylene (XLPE)
- Shape of conductor: Sector-shaped
- Nominal cross section conductor: 95 mm²
- Conductor surface: Bare
- Number of cores: 5
- Circuit integrity: None
- Cable geometry: Round
- Concentric conductor: None
- Screen: No
- Laminated sheath: No
- Lead sheath: No
- Drain wire: No
- Weight: 1741 kg/km
- Weight/100 m: 174 kg
- Flame retardant according to IEC 60332-1-2: Yes
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: None
- Min. permitted bending radius, stationary application/permanent installation: 272 mm
- Longitudinal water blocking conductors: No
- Reaction-to-fire according to EN 13501-6: Smoke production: None
- Inner semi-conducting layer: No
- Material outer sheath: Polyolefin
- Outer semi-conducting layer: No
- Fibre optic elements: No
- Oil resistant according to EN IEC 60811-404: Yes
- REACH Date: 2021-06-14