Ground cable AXQ 0,6/1 kV Dca
AXQ 1X95 0,6/1 KV DCA
Article number: Suppl. article no:
0011520
110733006
to see price and stock
Cables according to this standard are halogen-free and flame-retardant. In the event of a fire, only smoke is emitted, free from corrosive gases and with a low smoke density. For open fixed installation, indoors and outdoors, in pipes and in the ground. Caution should be exercised when plowing.
- Article number: 0011520
- Suppl. article no: 110733006
- Ean no: 7394479027181
- Material class QA1710
Technical data
- Cable type: AXQ
- Dimension conductor x area: 1x95 mm²
- Reaction-to-fire according to EN 13501-6: Class: Dca
- Outer diameter approximate: 16 mm
- Nominal voltage U0: 600 V
- Nominal voltage U: 1000 V
- With protective conductor: No
- Colour outer sheath: Black
- Conductor category: Class 2 = stranded
- Conductor material: Aluminium
- Shape of conductor: Round
- Max. permitted conductor temperature: 90 °C
- Core colour: Black
- Low smoke according to EN IEC 61034-2: Yes
- Armouring/reinforcement: None
- Halogen free according to EN IEC 60754-1: Yes
- Halogen free according to EN IEC 60754-2: Yes
- Halogen free according to EN IEC 60754-3: No
- Reaction-to-fire according to EN 13501-6: Acidity: a2
- Screen: No
- Conductor resistance at 20 °C: 0.32 Ohm/km
- Core identification: Colour
- Specification core insulation: Crosslinked polyethylene (XLPE)
- Core identification according to HD 308 S2: No
- Nominal cross section conductor: 95 mm²
- Conductor surface: Bare
- Identification/coding colour core: Grey
- Number of cores: 1
- With rodent protection: No
- Cable geometry: Round
- Permitted cable outer temperature after assembling without vibration: -20-70 °C
- Lead sheath: No
- Drain wire: No
- Suitable for underground installation: Yes
- Max. tensile strength during installation: 2.85 kN
- Weight: 386 kg/km
- Low temperature resistant according to EN 60811-504+505+506: No
- Flame retardant according to IEC 60332-1-2: Yes
- Reaction-to-fire according to EN 13501-6: Flaming droplets/particles: d2
- Flame retardant according to IEC 60332-3-21 (Cat A F/R): No
- Flame retardant according to IEC 60332-3-22 (Cat A): No
- Flame retardant according to IEC 60332-3-23 (Cat B): No
- Flame retardant according to IEC 60332-3-24 (Cat C): No
- Flame retardant according to IEC 60332-3-25 (Cat D): No
- Min. permitted bending radius, stationary application/permanent installation: 164 mm
- Circuit integrity according to EN 50200 annex E: No
- Circuit integrity according to EN 50200: None
- Circuit integrity according to IEC 60331-1: None
- Circuit integrity according to IEC 60331-2: None
- Circuit integrity according to IEC 60331-3: None
- Radial water blocking cable: Yes
- Permitted cable outer temperature during assembling/handling: -20-70 °C
- Reaction-to-fire according to EN 13501-6: Smoke production: s2
- Certified for shipboard application: No
- Certified as airport lighting cable: No
- Suitable as installation cable: No
- Protective barrier: None
- Material outer sheath: Polyolefin
- Oil resistant according to EN IEC 60811-404: No
- REACH Date: 2024-11-07
- REACH Information obligation: No