Feedback
AhlsellProductsElectricAutomation 29-4538 Sensors, machine safetySurveillance relays, pressure guardsLevel monitoring

Carlo Gavazzi
Level control relay type CLD4M
LEVEL CONTROL RELAY CLD4M 24VAC/DC MULTI 4IN/2UT
Article number: Suppl. article no:
3864377
CLD4MA2DM24
to see price and stock
Level relay conductive liquids - simplified setup/wider sensitivity!
µ-processor-based level relay for fluids with a wide sensitivity scale (e.g. sewage, chemicals, salt water, etc). The relay has a separate output for alarm if the tank starts to get empty or if overflow risks occur. Multifunction with combinations of filling and emptying, functions are easily set in with the lower function knob in the front. Output: AC1 2 x 8A: 1pc 1 pole alternating relay (SPDT) and 1pc closing for alarm (SPST).
Sensor sensitivity from 250O to 500 kO (middle potentiometer: mode L/S/H, NO/NC), fine adjustment of the upper potentiometer.
Sensor voltage max 5 VAC, 2 mA.
Reaction time approx. 1s
Operating temperature -20º to +50º C
Indication 3pcs LED, green lights up when the control voltage is connected, yellow lights up when the respective relay is closed.
Dimensions (mm) 36x81x60
Suitable conductive sensor 3864407-20. Sensor electrode is cut where the level is desired.
µ-processor-based level relay for fluids with a wide sensitivity scale (e.g. sewage, chemicals, salt water, etc). The relay has a separate output for alarm if the tank starts to get empty or if overflow risks occur. Multifunction with combinations of filling and emptying, functions are easily set in with the lower function knob in the front. Output: AC1 2 x 8A: 1pc 1 pole alternating relay (SPDT) and 1pc closing for alarm (SPST).
Sensor sensitivity from 250O to 500 kO (middle potentiometer: mode L/S/H, NO/NC), fine adjustment of the upper potentiometer.
Sensor voltage max 5 VAC, 2 mA.
Reaction time approx. 1s
Operating temperature -20º to +50º C
Indication 3pcs LED, green lights up when the control voltage is connected, yellow lights up when the respective relay is closed.
Dimensions (mm) 36x81x60
Suitable conductive sensor 3864407-20. Sensor electrode is cut where the level is desired.
- Article number: 3864377
- Suppl. article no: CLD4MA2DM24
- Ean no: 5709870381350
- Material class QP029B
Technical data
- Type: CLD4MA2DM24
- Type of electric connection: Screw connection
- Rated control supply voltage DC: 19.2-28.8 V
- Voltage type for actuating: AC/DC
- With detachable clamps: No
- Number of inputs for electrodes: 5
- Min. adjustable operate delay time: 1.3 s
- Max. permitted operate delay time: 1.3 s
- Min. adjustable off-delay time: 1 s
- Max. permitted off-delay time: 1 s
- Response value sensitivity adjustable: Yes
- Number of contacts as normally closed contact: 0
- Number of contacts as normally open contact: 1
- Number of contacts as change-over contact: 1
- Physical measurement principle: Conductive
- Width: 35.5 mm
- Height: 81 mm
- Depth: 60.2 mm
- Rated control supply voltage AC 60 Hz: 19.2-28.8 V
- Rated control supply voltage AC 50 Hz: 19.2-28.8 V