Feedback

Sormat
Through-bolt anchor S-KAK plus hot-dip galvanized
THROUGH BOLT S-KAK+ HDG 16/60 1PCS
Article number: Suppl. article no:
71971412
9640094149
to see price and stock
S-KAK+ – Hot-dip galvanized, European type-approved, ETA 16/0934 Option 1 – for cracked and non-cracked concrete.
Hot-dip galvanized for indoor and outdoor installations.
S-KA through-bolt anchor is a torque-controlled anchor for use in cracked and non-cracked concrete as well as natural stone.
S-KA+ easily passes through the material during through-installation and is easier to tap into the concrete thanks to its improved cone.
Two setting depths for sizes 8 mm, 10 mm & 12 mm, with the specified tfix measurement and dimension indicated on the anchor body.
Marking on the head shows which length and dimension have been installed, making inspection after installation easier.
Always follow the installation instructions for best results:
1) Drill a hole according to the table in the installation data below
2) Clean the hole with a brush and blow pump
3) Tap in the anchor
4) Tighten the anchor with the recommended torque using a torque wrench
I) Permissible loads in kN for concrete C20/25.
Shear load values apply to a single anchor without the influence of concrete edge.
Hot-dip galvanized for indoor and outdoor installations.
S-KA through-bolt anchor is a torque-controlled anchor for use in cracked and non-cracked concrete as well as natural stone.
S-KA+ easily passes through the material during through-installation and is easier to tap into the concrete thanks to its improved cone.
Two setting depths for sizes 8 mm, 10 mm & 12 mm, with the specified tfix measurement and dimension indicated on the anchor body.
Marking on the head shows which length and dimension have been installed, making inspection after installation easier.
Always follow the installation instructions for best results:
1) Drill a hole according to the table in the installation data below
2) Clean the hole with a brush and blow pump
3) Tap in the anchor
4) Tighten the anchor with the recommended torque using a torque wrench
I) Permissible loads in kN for concrete C20/25.
Shear load values apply to a single anchor without the influence of concrete edge.
- Article number: 71971412
- Suppl. article no: 9640094149
- Ean no: 6416031941498
- Replaces art.nbr: 504685
- Material class TD201B
- This is an alternative to item 504685
Technical data
- Packagin Size: 1 Pack/10 Pack/200 Pack
- Surface treatment: Hot-dip galvanised
- Thread size (metric): 16
- Length: 178 mm
- Thread length: 115 mm
- Max. material thickness: 60 mm
- Drill diameter: 16 mm
- Drill depth: 110 mm
- Assembly depth: 97 mm
- Base material: Cracked Concrete, Crack-Free Concrete, Natural Stone, Solid Brick