Feedback

Omron
Frequency converter J1
J1-AB007-E
Article number: Suppl. article no:
3336729
J1-AB007-E
to see price and stock
Frequency converter RS485 Modbus. Analog IO, PID control. PC software J1 editor.
- Article number: 3336729
- Suppl. article no: J1-AB007-E
- Ean no: 4549734865524
- Material class QO5720
Technical data
- Type: J1-AB007-E
- Number of phases input: 1
- Mains voltage: 200-240 V
- Nominal output current I2N: 4.2 A
- Max. output at linear load at rated output voltage: 0.75 kW
- Max. output at quadratic load at rated output voltage: 0.75 kW
- Height: 128 mm
- Width: 68 mm
- Depth: 116 mm
- Application in industrial area permitted: Yes
- Application in domestic- and commercial area permitted: No
- Max. output voltage: 240 V
- Degree of protection (IP): IP20
- Degree of protection (NEMA): Other
- Number of phases output: 3
- Supporting protocol for PROFIsafe: No
- Supporting protocol for CAN: No
- Supporting protocol for Data-Highway: No
- Supporting protocol for TCP/IP: No
- Supporting protocol for INTERBUS-Safety: No
- Integrated breaking resistance: No
- Supporting protocol for PROFINET IO: No
- Supporting protocol for SafetyBUS p: No
- Number of analogue inputs: 2
- Number of analogue outputs: 1
- Number of digital inputs: 5
- Number of digital outputs: 2
- Number of HW-interfaces other: 0
- Number of HW-interfaces serial TTY: 0
- Number of HW-interfaces parallel: 0
- Number of HW-interfaces industrial Ethernet: 0
- Max. output frequency: 400 Hz
- With PC connection: No
- With optical interface: No
- With control element: No
- Mains frequency: 50/60 Hz
- Relative symmetric net frequency tolerance: 5 %
- Relative symmetric net voltage tolerance: 10 %
- Number of HW-interfaces USB: 0
- Supporting protocol for ASI: No
- Number of HW-interfaces RS-485: 1
- Number of HW-interfaces RS-422: 0
- Supporting protocol for DeviceNet: No
- Supporting protocol for KNX: No
- Supporting protocol for INTERBUS: No
- Supporting protocol for Modbus: Yes
- Number of HW-interfaces RS-232: 0
- Supporting protocol for SERCOS: No
- Supporting protocol for SUCONET: No
- Number of interfaces PROFINET: 0
- Supporting protocol for LON: No
- Supporting protocol for other bus systems: No
- Supporting protocol for AS-Interface Safety at Work: No
- Supporting protocol for BACnet: No
- Supporting protocol for DeviceNet Safety: No
- Supporting protocol for EtherNet/IP: No
- Supporting protocol for Foundation Fieldbus: No
- Supporting protocol for PROFINET CBA: No
- Supporting protocol for PROFIBUS: No
- REACH Date: 2025-09-22
- REACH Information obligation: No