Protection modules LUCA, standard, 3 phase, class 10
UNIT 1,25-5A 24VDC CL10 STAND LUCA05BL
Article number: Suppl. article no:
3231072
LUCA05BL
to see price and stock
Protection modules, standard, 3 phase, class 10.
- Article number: 3231072
- Suppl. article no: LUCA05BL
- Ean no: 3389110363838
- Material class QO360B
Technical data
- Packagin Size: 1 ST/23 ST/160 ST/320 ST
- Type: LUCA05BL
- Design: Standard
- Overload release current setting: 1.25-5 A
- Rated permanent current Iu: 5 A
- Number of poles: 3
- Voltage type for actuating: DC
- Rated control supply voltage DC: 24 V
- Type of motor protection: Thermal/magnetic release
- Short-circuit release function: Undelayed
- With ground fault protection function: TRUE
- Rated control supply voltage AC 60 Hz: 0 V
- Initial value of the undelayed short-circuit release - setting range: 65 A
- Number of auxiliary contacts as normally open contact: 0
- Number of auxiliary contacts as normally closed contact: 0
- Rated operation power at AC-3, 400 V: 1.5 kW
- Adjustable current range: 1.25-5 A
- Rated operation current Ie: 5 A
- Number of command positions: 0
- End value adjustment range undelayed short-circuit release: 65 A
- REACH Date: 2022-07-20
- Rated operation power at AC-3, 230 V, 3-phase: 0 kW
- REACH contains candidate substances: Bly
- Ambient temperature, upper operating limit: 70 °C
- Rated control supply voltage AC 50 Hz: 0 V
- Control voltage: 24 V DC
- Number of indicator lights: 0
- Supporting protocol for ASI: TRUE
- Coordination class according to IEC 60947-4-3: Class 2
- External reset possible: FALSE
- Supporting protocol for PROFIBUS: TRUE
- Degree of protection (IP): IP20
- Supporting protocol for INTERBUS-Safety: FALSE
- Temperature compensated overload protection: TRUE
- Supporting protocol for INTERBUS: FALSE
- Suitable for rail mounting: FALSE
- Supporting protocol for AS-Interface Safety at Work: FALSE
- Supporting protocol for PROFINET CBA: FALSE
- With fuse: FALSE
- REACH Information obligation: Yes
- Supporting protocol for Data-Highway: FALSE
- Supporting protocol for SUCONET: FALSE
- Supporting protocol for Modbus: TRUE
- Supporting protocol for TCP/IP: FALSE
- Supporting protocol for DeviceNet: TRUE
- Supporting protocol for other bus systems: TRUE
- Supporting protocol for SERCOS: FALSE
- Supporting protocol for Foundation Fieldbus: FALSE
- Supporting protocol for DeviceNet Safety: FALSE
- Type of electrical connection of main circuit: Other
- Type of motor starter: Other
- Supporting protocol for PROFINET IO: FALSE
- Supporting protocol for CAN: TRUE
- With short-circuit release: TRUE
- Supporting protocol for PROFIsafe: FALSE
- Supporting protocol for SafetyBUS p: FALSE
- With transformer: FALSE
- Suitable for emergency stop: FALSE
- Supporting protocol for LON: FALSE
- Release class: CLASS 10
- Supporting protocol for EtherNet/IP: FALSE