Motor protection

Do you work in ventilation and air treatment systems? Ahlsell helps you find what you need within rules and regulations. We have the products whether you work on projects, contracting, or service and maintenance. Here you will find regulators for electric heating and everything needed for an excellent indoor climate. You will also find thermostats and sensors in our product range. The majority of products within electric heating are available in our range. Explore our wide range of electric heating, controls, and regulations here in the online store or visit your nearest Ahlsell store.

Motor Protection U-EK230E EX, Systemair
Systemair
Motor Protection U-EK230E EX, Systemair
Art. no.: 6511067
U-EK 230E is a thermistor motor cover to be used in conjunction with a contactor to protect Ex-fans, can also be used for fans with built-in thermistor. It is designed as an electronics unit designed to be snap-mounted on a 35 mm DIN rail. I The fan motors have six series-connected thermistors, two per phase winding, whose resistance is affected by the temperature. When the motor temperature exceeds the permissible temperature, the resistance rises steeply and the motor protection triggers. When the motor cover has tripped, the indicator lamp labeled "Interference" lights up. Resetting is done manually, either by pressing the "Reset" button, or by turning the motor cover off (switching the supply to A2) for about 10 seconds. If a five-stage transformer is used to control the EX fan, the U-EK 230E must be connected to the transformer.
New in the online store
Alarmkkontakt K(ZB) STDT för S-ET & S-DT, 1xNC/1xNO Systemair
Systemair
Alarmkkontakt K(ZB) STDT för S-ET & S-DT, 1xNC/1xNO Systemair
Art. no.: 19065681
U-EK 230E is a thermistor motor cover to be used in conjunction with a contactor to protect Ex-fans, can also be used for fans with built-in thermistor. It is designed as an electronics unit designed to be snap-mounted on a 35 mm DIN rail. I The fan motors have six series-connected thermistors, two per phase winding, whose resistance is affected by the temperature. When the motor temperature exceeds the permissible temperature, the resistance rises steeply and the motor protection triggers. When the motor cover has tripped, the indicator lamp labeled "Interference" lights up. Resetting is done manually, either by pressing the "Reset" button, or by turning the motor cover off (switching the supply to A2) for about 10 seconds. If a five-stage transformer is used to control the EX fan, the U-EK 230E must be connected to the transformer.
Showing 4 of 4